Technology · DALI

DALI: digital, addressable lighting control.

DALI is the international standard for digital lighting control. Fortue can design DALI and DALI-2 systems for offices, hotels, retail and residences, and integrate them with KNX and building automation.

What it is

Every light fitting gets its own address.

DALI (Digital Addressable Lighting Interface) is defined in IEC 62386. DALI-2, certified by the DALI Alliance, extends the standard to sensors and push buttons so control devices from different manufacturers work together.

A two wire DALI line carries digital commands to up to 64 drivers, each individually addressable and assignable to up to 16 groups and 16 scenes. Device Type 8 (DT8) adds colour control for tunable white and RGBW fixtures. A DALI controller or a KNX/DALI gateway manages each line.

Fit

Why clients choose DALI

DALI gives precise, addressable control and feedback, so lighting can be regrouped and rescened without rewiring.

Problems it solves

Fixed circuits that cannot be changed when a space is replanned; dimming problems from mismatched drivers; no visibility of failed fittings in large buildings.

Modular white contemporary architecture

Wiring

DALI uses two control wires that can run in the same cable as mains (with correct insulation), and polarity does not matter. Each line needs a DALI power supply and is limited to 64 drivers, so large projects use multiple lines.

Security considerations

DALI lines are local and not internet facing. Security risk sits at the controller or gateway, which should sit on a segmented network with secured remote access.

Advantages

Limitations

Lifecycle

Designing, installing and supporting DALI.

What has to be right at each stage for the system to work for years.

01

Design

Control zones, groups, scenes, sensor positions and driver types.

→ Lighting control design

02

Specification

DALI compatible drivers specified with the lighting schedule.

→ Driver schedule

03

Installation

DALI lines, power supplies and controllers installed.

→ Installed lines

04

Commissioning

Addressing, grouping, scenes and sensor tuning on site.

→ Commissioned lighting

05

Maintenance

Fault reports, driver replacement and readdressing.

→ Fortue Care

06

Expansion

Additional lines and fittings added as spaces change.

→ Extended system

Fortue’s role

Engineering the system, not just the devices.

Fortue can design DALI control strategies, specify compatible drivers with the lighting designer, commission the system and integrate it with KNX, BACnet or a central dashboard.

DALI is often combined with KNX (via gateways) in villas and hotels, and with BACnet supervision in commercial buildings.

01

When Fortue recommends it

Offices, hotels, retail and premium residences that need dimming, scenes, tunable white or failure reporting.

02

When we recommend something else

Fast colour changing façade effects are better served by a dedicated dynamic lighting control system; simple switching may not need DALI at all.

03

Typical applications

Offices, hotel rooms and public areas, retail, villas.

Questions

DALI questions.

DALI-2 adds certified control devices such as sensors and push buttons and tighter interoperability testing by the DALI Alliance.

Yes, with Device Type 8 (DT8) drivers and a compatible controller.

Yes. KNX/DALI gateways let KNX keypads and logic control DALI lighting.

DALI

Considering DALI for your project?

Share your drawings or describe the building. A Fortue engineer will recommend an architecture, whether or not it is DALI.