Technology · BACnet

BACnet: the language of building management systems.

BACnet is the open protocol most HVAC plant and building management systems use. Fortue can integrate BACnet devices and supervisory systems with lighting, KNX and energy monitoring.

What it is

An object model for building services.

BACnet is defined by ASHRAE Standard 135 and ISO 16484-5. It describes building equipment as objects, inputs, outputs, schedules, alarms, trends, with standard properties any compliant system can read and write.

BACnet/IP runs over Ethernet networks; BACnet MS/TP runs over RS-485 serial cabling for field controllers. A supervisory system reads points from chillers, AHUs and controllers, runs schedules and raises alarms. BACnet/SC adds secure, certificate based connections.

Fit

Why clients choose BACnet

BACnet is the common ground between plant manufacturers, controls contractors and facility teams.

Problems it solves

Plant from different vendors with separate front ends; no central alarm view; building services that cannot share schedules with lighting and access.

Monitoring dashboard on a tablet

Network and wiring

BACnet/IP uses the building IP network and should sit on its own segment; MS/TP uses daisy chained RS-485 with correct termination and addressing.

Security considerations

Legacy BACnet has no built in security, so segmentation and firewalls are essential. BACnet/SC encrypts traffic on new installations.

Advantages

Limitations

Lifecycle

Designing, installing and supporting BACnet.

What has to be right at each stage for the system to work for years.

01

Points list

Agree points, alarms and schedules with MEP and operator.

→ Points list

02

Design

Network segmentation, MS/TP trunks and gateways.

→ Integration design

03

Installation

Controllers, gateways and network connections.

→ Installed system

04

Commissioning

Point verification, alarms and trends.

→ Commissioned BMS links

05

Maintenance

Alarm reviews and controller updates.

→ Fortue Care

06

Expansion

New plant added to the same supervision.

→ Extended system

Fortue’s role

Engineering the system, not just the devices.

Fortue can integrate BACnet plant and controllers into a supervisory layer and connect it to lighting, KNX and energy data. Fortue presents BACnet as an ecosystem standard it integrates, not as a published BMS project reference.

Gateways connect BACnet with KNX, Modbus and MQTT so HVAC, lighting and energy share one view.

01

When Fortue recommends it

Commercial, hospitality and mixed use buildings with central HVAC plant.

02

When we recommend something else

Villas with split or VRF systems usually integrate HVAC through KNX or Modbus gateways instead.

03

Typical applications

Offices, hotels, residential towers, mixed use podiums.

Questions

BACnet questions.

BACnet/IP runs over Ethernet; MS/TP runs over RS-485 serial cabling, typically for field controllers.

Yes, through BACnet/KNX gateways.

BACnet

Considering BACnet for your project?

Share your drawings or describe the building. A Fortue engineer will recommend an architecture, whether or not it is BACnet.