Technology · BACnet
BACnet: the language of building management systems.
BACnet is the open protocol most HVAC plant and building management systems use. Fortue can integrate BACnet devices and supervisory systems with lighting, KNX and energy monitoring.
What it is
An object model for building services.
BACnet is defined by ASHRAE Standard 135 and ISO 16484-5. It describes building equipment as objects, inputs, outputs, schedules, alarms, trends, with standard properties any compliant system can read and write.
BACnet/IP runs over Ethernet networks; BACnet MS/TP runs over RS-485 serial cabling for field controllers. A supervisory system reads points from chillers, AHUs and controllers, runs schedules and raises alarms. BACnet/SC adds secure, certificate based connections.
Where it is used
What BACnet can control.
Fit
Why clients choose BACnet
BACnet is the common ground between plant manufacturers, controls contractors and facility teams.
Problems it solves
Plant from different vendors with separate front ends; no central alarm view; building services that cannot share schedules with lighting and access.
Network and wiring
BACnet/IP uses the building IP network and should sit on its own segment; MS/TP uses daisy chained RS-485 with correct termination and addressing.
Security considerations
Legacy BACnet has no built in security, so segmentation and firewalls are essential. BACnet/SC encrypts traffic on new installations.
Advantages
- Open, widely adopted in HVAC
- Standard object model
- Scales to large buildings
- Supported by most plant controllers
Limitations
- Points lists must be agreed carefully
- Device support levels vary (check BTL listing)
- Legacy installations lack security
- Engineering effort for mapping
Lifecycle
Designing, installing and supporting BACnet.
What has to be right at each stage for the system to work for years.
01
Points list
Agree points, alarms and schedules with MEP and operator.
→ Points list
02
Design
Network segmentation, MS/TP trunks and gateways.
→ Integration design
03
Installation
Controllers, gateways and network connections.
→ Installed system
04
Commissioning
Point verification, alarms and trends.
→ Commissioned BMS links
05
Maintenance
Alarm reviews and controller updates.
→ Fortue Care
06
Expansion
New plant added to the same supervision.
→ Extended system
Fortue’s role
Engineering the system, not just the devices.
Fortue can integrate BACnet plant and controllers into a supervisory layer and connect it to lighting, KNX and energy data. Fortue presents BACnet as an ecosystem standard it integrates, not as a published BMS project reference.
Gateways connect BACnet with KNX, Modbus and MQTT so HVAC, lighting and energy share one view.
01
When Fortue recommends it
Commercial, hospitality and mixed use buildings with central HVAC plant.
02
When we recommend something else
Villas with split or VRF systems usually integrate HVAC through KNX or Modbus gateways instead.
03
Typical applications
Offices, hotels, residential towers, mixed use podiums.
Questions
BACnet questions.
What is the difference between BACnet/IP and MS/TP?
BACnet/IP runs over Ethernet; MS/TP runs over RS-485 serial cabling, typically for field controllers.
Can BACnet work with KNX?
Yes, through BACnet/KNX gateways.
BACnet
Considering BACnet for your project?
Share your drawings or describe the building. A Fortue engineer will recommend an architecture, whether or not it is BACnet.